Series HMI Connection Manual Cimon PLC (This PLC is applicable to BP, XP series of PLC) HMI Factory Setting: Baud rate: 38400. 8. None. 1 Controller Station Number: 1 Control Area / Status Area: D00000/D00010 Connection a. RS-232 (DOP-A/AE/AS, DOP-B Series) DOP series Controller 9 pin D-sub male (RS-232) RXD (2) (7) TXD TXD (3) (4) RXD GND (5) (2) GND (3) RTS (6) CTS Definition of PLC Read/Write Address a. Registers V1.00 Revision March, 2010 15 Format Type Read/Write Range Data Length Note Word No.

(n) Input X Xn X000 – X511 Word Output Y Yn Y000 – Y511 Word General Purpose Relay M Mn M000 – M999 Word General Purpose Relay L Ln L000 – L999 Word Latch Relay K Kn K000 – K999 Word Flags F Fn F000 – F127 Word Timer (Set) TS TSn TS0000 – TS4095 Word Timer (Current) TC TCn TC0000 – TC4095 Word Counter (Set) CS CSn CS0000 – CS4095 Word Counter (Current) CC CCn CC0000 – CC4095 Word