Downloaded from https://www.everyspec.com MIL-STD-3001-2A(AS) 5.2.2.3 Support equipment required list ( operation data only ). All support equipment (SE), including special tools required to perform operational type procedures, shall be listed ( standard list ) immediately following the record of applicable technical directive data. If no support equipment is required, the heading "Support Equipment Required" shall be omitted from the WP. Only those special tools (including torque wrenches) and equipment authorized for use at the level of maintenance covered shall be listed. Items shall be listed in alphabetical sequence by noun nomenclature. Standard hand tools shall not be listed.
Illustrations shall not be prepared in support of such lists. When the WP is used by other services or commands that require usage restrictions, the item shall be identified by a symbol following the part number in parentheses. The usage of the symbol shall be explained in a notation (e.g., "(AF)=USAF only," "(NS)=NAVSEA only," "(MC)=MARINE CORPS only"). 5.2.2.3.1 Each support equipment entry in the list shall be identified by "Nomenclature," "Part Number," and "CAGE Code." When more than one of the same item is required, the quantity shall follow the nomenclature in parentheses. If a “CAGE Code” is not available, a dash shall be substituted for the “CAGE Code”.
5.2.2.3.2 If the WP contains multilevel maintenance procedures and any of the SE items are authorized for use at only certain level(s), the restrictive use shall be indicated by the use of an O, I, and/or D in parentheses following the item nomenclature. For Aircraft Engine Manuals , the following special application codes to identify usage restrictions shall be used: a. "J" shall be used to indicate the first degree engine maintenance level, b. "8" shall be used to indicate the second degree engine maintenance level, and c. "9" shall be used to indicate the third degree engine maintenance level. 5.2.2.4 Facilities required list faclist > (operation data only) .
All facilities needed to accomplish the maintenance procedures shall be listed (standard list) immediately following the support equipment required list. If no facilities are required, the heading "Facilities Required" shall be omitted from the WP. Each facility entry in the list shall be identified by "Nomenclature," "Part Number," and "CAGE Code." 5.2.2.5 Materials required list (operation data only) . All materials (consumable materials and/or expendable items) required to perform maintenance type procedures shall be listed (standard list) . If no materials apply, the heading "Materials Required" shall be omitted from the WP.
Items shall be listed in alphabetical sequence by noun nomenclature. The materials required list shall be prepared in accordance with the guidelines listed below. If the material is a hazard material the hazard material warning summary (HMWS) shall be included. a. Each material entry in the list shall be identified by "Nomenclature," "Specification/Part Number," and "HMWS Index Number," as applicable. 5