US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors (EN)

Downloaded from https://www.everyspec.com AMCP 706.117 lisher, Inc., Agent, Washington, D.C. These transport- equipment transported by common carrier, land, and ability regulations and specifications have been ex. air. Separate tests are required for packages tied down cerpted from Ret. 79. during transport and for loose cargo. The test for tied- Most vibration test specifications include some com- down cargo includes a combined cycling and resonance bination of bounce, cycling, or resonance testing as test, and the loose cargo test is comprised of a bounce described in par. 4-6.2. The three most widely used test and a resonance search.

Separate amplitude versis vibration test standards today are MIL-STD.8 10, Enyl- frequency schedules are prescribed for air transport ronmental Test Methods Method 514 (Ref. 51); Federal and for three ci-.sses of land transport. Table 4-12 sum- Test Method, Standard 101B (Method 5020 and Method marizes these tests. 5019) (Ref. 80); and MIL-STD-331 (Test 104.1) (Ref. The vibration tests of Federal Test Method, Stand- 81). MIL-STD-810 (Method 514) prescribes tests for ard 101B, are also widely used. Method 5020 includes many categories of equipment in aircraft and missiles low and high frequency range cycling tects and a reso. and in addition has a stparate category for packaged nance test.

Method 5019 is a bounce test. Vibration tests TABLE 4-12. PACKAGE VIBRATION TEST FROM MIL-STD-810 (Ref. 66) CARGO TIED DOWN 1. Amplitude vs frequency schedules are as shown in this speci- fication for four classes of transport: air; tracked vehi- cles; trucks, tractor-trailers, and railroad; and two wheeled trailers. Package weight is taken into account in the air transport schedule. 2. Test frequency range is 2-500 Hz, except for air transport of packages whose weight exceeds 100 lb. In the exceptional cases, the upper limit frequency is decreased with increasing weight. 3. Test time is 15 min per axis per 1,000 ml of land transport and 1 hr per axis per 1,000 mi of air transport.

If both modes are included, the land transport test time shall apply only to the frequency range from 2 Hz to the intersection with the air transport schedule, and the air transport time applies to the frequency range from that intqrsection to the upper limit frequency. 4. Resonance search is conducted by a single sweep of the fre- quency range for each axis at amplitudes reduced from the schedul es. 5. Resonant dwell is taken at the four most severe resonances along each axis if that many are clearly defined. Dwell time is 2.5 min per 1,000 mi of land transport or 10 min per 1,000 mi of air transport. 6. Cycling test is used for the remainder of the test time.

A logarithmic sweep at the rate of 15 min per sweep is pre- ferred, although a piecewise-linear sweep is acceptable. 4.71