Downloaded from https://www.everyspec.com AMCP 70-117 TABLE 4-13. VIBRATION TESTS FROM FEDERAL TEST METHOD STANDARD 101B (Ref. s8) METHOD 5020 1. The low-frequency cycling extends over the range from 2-5 Hz. Test lcvel. is 1-in. double amplitude and the test time is 15 min per axis. The sweep Is to be a logarithmic sweep at 2 min per octave. However, a discrete frequency alternate is acceptable; 5 min each at 2, 3, and 5 Hz. 2. The high frequency cycling test schedule from 5-500 Hz Is as illuscrated in the specifitation, except that the upper limit frequency is taken as In the aircraft portion of the MIL-STO- 810 test. Test time is 15 min per axis.

Again a logarithmic sweep is preferred, and although the sweep rate is not speci- fied, it is required that at least four 5-max freq. - 5 Hz sweeps be executed. Two alternates are allowed in the sweep: Time, s Freq., Hz Double amplitude, in. 70 5-7.56 0.673 Piecewise- 70 7.56-11.44 0.295 linear W 11.44-17.3 0.129 sweep 70 17.3-26.6 0.055 105 26.6-50 0.036 70 6.15 0.673 Discrete 70 9.3 0.295 freq. 70 14.07 0.129 sweep 70 21.6 0.055 70 32.7 0.036 70 49.5 0.036 3. The resonance test specifies a 15-mtn dwell at each resonant frequency. LOOSE CARGO 1. Counce test is taken at 1-in. double amplitude (i.e., peak-to peak displacement) at 284 rpm (4.73 Hz).

Test time is 30 min on each face, for a total test time of 3 hr. 2. Resonant search Is conducted over thu. range from 10-55 141 with a minimum double amplitude of 0.003 In., b increments of 1-Hz steps and maintaining at least 10 s at eac frequency. This test is run solely to establish that the resonant amplication factors do not exceld 2.0. 4-73