Downloaded from https://www.everyspec.com Dier7W.-t17 TABLE 7-13. LOW FREGUENCY AND INFRAONIC NOI8E EXPC3URE LIMITS (Ru. 9) Frequency,* SPL, Durationt Notes Hz dB min/day 1- 7 1SO 4 8 - 11 145 4 Use of ear plugs will reduce unpleasant sensations 12- 20 140 4 21 - 100 135 20 Without protection 21 - 100 150 20 With ear plugs *Refers to pure tones, or to octave bands with center frequencies as Indicated. tRefers to one exposure per day, with at least 24 hr elapsing be- tween successive exposures. ISO IIiA - I URATIOI ' mull1 CURVll ASIIJIS 100 DULII PER DAY AND OTHSR CONDITION$ AS ITATS IN THIK 5V 0.023 0.03 0.1 0.2 0.3 1 2 3 10 20 0100 200 S00 1.000 DURIlATIO, ma FIGURE 7.24.
Bak LImin for ImWulwko Expo.. 7-37