Downloaded from https://www.everyspec.com AMCP 700-117 7-7.4 WORKSPACE NOISE CRITERIA 7.7.6 HEARING PROTECTION Beranek (Ref. 96) presents criteria for limiting back. Four general approaches may be taken to prevent ground noise in wotkspaces in which communication In- unwanted sound from reaching the ear. The person terferenre, loudness, or annoyance of noises is an Im- may he removed to a distance from the noise source so portent design consideration. These noise criterion (NC) that spherical divergence and excess attenuation reduce curves are widely used as workspace design criteria. Fig. the noise level to an acceptable extent.
A physical bar- 7.27 shows the allowable octave-band SPL (for both rier may be placed between the noise blast source and commercial and preferred octave bands), and Table 7-14 the person. The natural "aural reflex" action of the identifies typical workspaces with the appropriate NC human middle-car muscles may be stimulated as a cmIvs. These curves are derived in such a way that each means ofprotection. Finally, a mechanical hearing pro- octave band contributes equally to the loudness of the man o e protedton. oin, a eanical h eng - background noise. To be acceptable, the noise level in tector may be placed over, or in, the ear canal to attenu- ate ambient sound energy.
Implementation of this me- each octave band must not exceed the level permitted by Lhanical approach is treated here. the selected NC curve. When commercial frequencies are (I) Mechanical hearirag protection. in situations in used, the NC number Is also the SIL for that particular which it is neither economical nor practical to remove spectrum. people to a distance from a noise source or to place a As a general rule, solving the problem of excessive harrier between them and the source, the use of me- noise in workspaces is best left to the specialist---the ch-nical hearing protection is recommended to reduce acoustics engineer.
Theoretical solutions to sound trans- the noise to a level that is not hazardous to hearing mission through structures typically are difficult to ob- and/or will permit effective communication. tain. For example, a recent paper describes a theoretical Hearing protectors will often improve person-to-per- method for computing the sound transmission lost son and loudspeakerpto-person communication in noise through a double-leaf wall" (Ref. 98). Even for thisonadlusekrt-esncmuiainios (Ref. 104). The same speech signal-to-noise rtlio reaches problem, various simplifications are necessary to obtain the ear with and without protection in such cases, but an analytical solution. Fig.
7-28 compares the analytical the use of protection may cause the speech signal to results with experimental ones for various leaf weights reach the ear at a level in the optimal range for speech and spacinip. intelligibility (overall rms level of about 70 dB). This The ranges of sound levels produced by various effect may, therefore, influence the selection of hearing building equipment are shown in Table 7-15. The ranges protection for use in a given situation.
For example, of sound level reductions obtained from various build- recommending a highly effective hearing protector for ing features and sound isolation treatments are shown use in a relatively low noise level wculd t'o undesirable, in Table 7-16. ,since this might reduce the speech signal to below the 7-7.5 COMMUNITY NOISE CRITERIA optimum speech level. Mechanical hearing protectors fall into tour general 'Tle final decision on criteria for community noise categories---earplugs, semi-inserts, earmuffs, and hel- exposure is an administrative one. Scientific and techni- mess.
cal data may aid in answering questions, but legal and administrative officials must make the final decisions (a) Earplugs. Earplugs ar s available in two forms: concerning community noise (Ref. 00). (I) preformed rubber or plastic plugs suplied in up to As a guideline on community noise, the following seven sizes, and (2) disposable plugs, such as wax- references are relevant: impregnated cotton, or "glass down" (a very fine. (1) FAA noise limits ror new commercial aircraft nonirritating glass wool). Dry cotton is not recom- (Ref. 101) mended for use since it provides negligibie sound at- (2) Department of Defense permitted noise level tenuation (2 to 5 dB in the lower frequencies.
6 to 10 limits for land-use planning around airports (Ref. 102) dB at the higher frequencies) and may provide a false (3) Zoning ordinances for limiting community sense of security. noise (Ref. 103). In order to be maximally effective, earplugs must be properly fitted for size. It is nut unusual to find people .A double-leaf wall is one containing two planar who require a different size of plug for each ear. Fur- members separated (usually) by an air space, such as thermore, the plugs must be properly inserted each occurs in dly-wall (sheetrock) construction, time they are used- they must be tight to be effective. 7-39