US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors (EN)

Downloaded from https://www.everyspec.com AMCP 706,117 TABLE 8.12. RECOMMENDED MAXIMUM PERMISSIBLE INTENSITIES FOR RADIO FREQUENCY RADIATION (Ref. 39) Maximum Frequency, Country or source Specifications permissible MHz Intensity 10-100,000 LISASI 1966; Canada 1966 1 mWhr cm" 2 for each 6 min 30-30,000 Great Britain 1960 Daily exposure 10 oM cm" 2 10-100 mW cm" 2 Lim. U.S. Army and Air Force 1965 10 mW cm"2 cont. exp. Occupancy [exposure (min hr- 1 )) 2 Ali [power density (mW cm' _ 6,000 Sweden 1961 Occas. exp. 700-30,000 U.S. Electronics Whole body and Coimunicat. Ind. 1956 1 mw cm" 2 All Sweden 1961 General public prolonged occupat. exp. 0.5 mW cm" All NATO 1956 --- > 300 U.S.SR.

1965; Poland 1961 15-20 min/day 0.1 mW cm-Z > 300 U.S.S.R. 1965; Poland 1961 2-3 hr/day 0.025 mW cm"2 > 300 Czechoslvakia 1965 CW, 8 hr/day 0.01 mW cm" 2 > 300 U.S.S.R. 1965 6 hr/day Poland 1961 Entire day Czechoslovakia 1965 Pulsed, 8 hr/day 20 V m- 1 3.1-30 U.S.S.R. 1969 10 V m" 1 0.01-300 Czechoslovakia 1965 Pulsed, 8 hr/day 5 V m" 1 30-300 U.S.S.R. 1965 *Original references for these data are in Ref. 39. 846