US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors (EN)

Downloaded from https://www.everyspec.com AMCP 7-117 any generalized heating of the animal. Of course, some sure time. In the experiments, no difference was researchers deny that nonthermal effects exist. Among observed in the overall effects of the two frequencies of these, opinion is divided into (I) those who deny the 750 and 1000 MHz. In addition, no difference was existence of any low level effects whatsoever that con- observed between continuous radiation and pulsed stitute a hazard to man, and (2) those who admit the radiation (2 to 12 Hz).

Microwave radiation at the low possibility of low level effects of microwaves but who intensity of 3 mW cm- 2 seemed to produce two effects consider these effects merely to be due to microthermal on performance: (1) a stimulation during short expo. effects. Indeed, the Russian literature contains a con- sure, and (2) an inhibition during longer exposure. The troversy as to whether the low level effects observed by author zoncludes that further deterioration of perform. various Russian researchers can be attributed to micro- &ane can be expected under the following circum. thermal effects or to nonthermal effects. A. S. Presman, stances:

(I) if the psychological tasks are made more one of the leading researchers in the field of the effects complex, or (2) if the intensity of rediation is increased. of microwaves on living organisms in the U.S.S.R., The rate of performance decrease was found to be pro. appears to attribute the stress stimuli from microwaves, portional to the power level and to the duration of regardless of the frequency or power level, not only to exposure. the stimulation oT thermal receptoks in the skin but also A number of experiments have Involved experimental t,j other sensory skin receptors. He discusses tile iam- animals in which microwaves have been obferved to pro.

pulses that flow from the skin receptors to the cortical duce various neuroelectulc reponses. Microwave Intensl. areas of the brain and then to specific target organs or ties ab low as 30 mW cmni average and 60 mW cmra peak systems (Ref. 44). have produced evoked responses In the brain stem of Observations of behavioral disturbances associated cats. Microwave stimulation has produced alteration In with exposure to microwave radiation of low or moder- the electroencephalogram. Microwave stimulation Is of- ate intensities have been reported.

In some of these ten followed by Increased amplitude and decreasd fre- investigations, a threshold irritant as low as 0.01 to quency of EEG components or by decreased amplitude 0.025 mW cm-' can induce behavioral changes. The and Increased frequency. In addition, exposure to radla- olfactory sensitivities of 358 workers exposed to mi- tion produces increamed conduction speed, decreae In crowaves are reported to be less than among members refractorlne,,, and changes in action current amplitude of a cortrolled group (Ref. 45). In a survey of the in frog nerve fiber with exposures of 1 to 11 mW cm" !iterature on the influence of low intensity microwaves (Ref. 46).

on nervous function, several experiments in which mi- Additional discussions of biological experiments and crowaves were employed to induce hallucinatory biophysical mechanisms are contained in a special issue sounds in subjects were discussed (Rit'. 46). on the biological effects of microwaves in the IEEE Transactions on Microwave 7Theooy and Techniques Buzzing, ticking, hissing, or knocking sounds are (Ref. 47). Effects of low intensity microwave radiation sensed by human beings exposed to mean power densi- (Ref. 48) and pulse modulated UHF energy (Ref. 49), ties as low as 0.1 mW cm- 2 . It appears that the peak effects on the central nervous system (Ref.

50), and power density is a more critical measure than mean Russian cesearch (Ref. 40) are discussed in the litera. power density in these measurements. The peak power ture as cited. threshold for the hallucinatory sounds do not appear to be associated with the eyes, ears, or teeth, but they can be blocked by shielding a small arts of the cerebral 8-5 DESIGN cortex just above the temporal lobe. A recent report details the effects of low intensity Methods for the suppression of the effects of electro- microwaves on performance (Ref. 47).

In this investiga, magnetic radiation are diverse, encompassing a com- tion rhesus monkeys were exposed to microwave radia- pier technology for electronic materiel, a cautious de- tion for 10 to 95 min, during which time the monkeys sign approach for other materiel, and an awareness of were performing an operant-conditioned task in order safety measures with respect to personnel hazards.

In to establish the effects of microwaves on activity level, this paragraph, these varioum design considerations are The intensity levels of microwave exposure were 10 and outlined and spLcific references are cited to provide a 13 mW cm- 2 at 750 MHz, and 3 and 8 mW cm- 2 at starting point for more detailed analysis of specific de- 1,000 MHz. The results of the tests indicated that expo- sign problem arms. The edectronic design engineer is sure to micivwaves decreased performance rate di. normally aware of the interference and compatibility recily proportional to the field intensity and the expo. problems aaiociatev with the equipment that he is de. 84a8