US Army Materiel Command AMCP 706-117 — Environmental Series, Part Three: Induced Environmental Factors (EN)

Downloaded from https://www.everyspec.com AMCP 706-117 100-, 00 90 - -"-" 90 BO 0 80 70 70 60 60 50 50 3030 20 AO-N - -r. RANGEA 20 S-.- -- -- R A N G E B 1 0 10 - 0.7 2 3 5 10 20 30 50 100 PARTICLE DIAMETER, um FIGURE 3.5. Particle Size Distribution of Dust Clouds Generated by Tanks TABLE 3-6.

PARTICLE SIZE DISTRIBUTIONS OF DUST COLLECTED AT AIR INLETS OF ARMY TANKS (percent within range) Size range, M4A1 Tank, M48 Tank, M48 Tank, Coarse test Vill engine air, engine air, crew air, dust, % % *%%** 0-10 12.5 42.4 60.2 24 10-20 28.0 13.7 15.7 14 20-40 43.0 16.8 12.2 23 > 40 11.5 27.1 10.9 39 *Coarse dust for testing air cleaners per Society of Automotive Engineers "Air Cleaner Test Code," also known as AC Coarse dust. *•*No explanation was given in the reference for data in these columns not adding up to 100%. 3-8