Downloaded from https://www.everyspec.com AMCP 706-1tI .00 i io A , Sample-point Numbers Figure 2.12(a). Kolmogorov&Slrnov Goodnest-of-Fit Test, Shortcut Calculation Table 2-12 can be used to put s-confidence This is a pair of points on line S; see Fig. limits on the actual Cd, The steps in tho 2-12. procedure are: b, Compu te Fmj + d, and FL, + d. I. Select the desired s-confidence level This Is a pair of points on line U, the upper and pick the value of d from Table 2-12, It s-confidence line; see Fig. 2-12, will also depend on the sample size N. A s-confidence level of about I -- (I/N) is teo- c, Compute Fq - d, and PF - d. sonable.
This Is a pair of points on line L, the lower s-confidence live; see Fig. 2-12. 2. At each sample-point number r: 3. Connect all the points on line U, Con- a. Compute the sample Cd[ as: nect all the points on line L, Each pair of points In step 2b or 2c is plotted at xr, the FR r1/N, F1, (r - 1)/t. (2-48) value of the random variable at sample-pohit 2-72'1