Hantek — :TIMebase:MODE

For example :TIMebase:MAIN:OFFSet 0.0002 /*set the main time base offset to 20ms*/ :TIMebase:MAIN:OFFSet? /*The query returns 2.0000000e-04* :TIMebase [: MAIN]: SCALe 0 For example :TIMebase:MAIN:SCALe 0.0002 /*Set the main time base scale to 200μs / div*/ :TIMebase:MAIN:SCALe? /*The query returns 2.0000000e-04*/ :TIMebase:MODE For example :TIMebase:MODE XY /*Set the horizontal time base mode to XY mode*/ :TIMebase:MODE? /*The query returns XY*/ 66 / 136 "slow Scan mode) STOP: (-MemDepth / SampleRate) to (1s + 0.5 × MemDepth / SampleRate) ― Roll mode RUN: This command is not available STOP:

(-12 × MainScale) to 0 Among them, MemDepth is the current storage depth of the oscilloscope, SampleRate is the current sampling rate of the oscilloscope, and MainScale is the current main time base scale of the oscilloscope.  When the horizontal time base mode is YT and the horizontal time base is 200ms / div or greater (that is, "slow sweep" mode), this command is not available during the oscilloscope stop process. Return format The query returns the main time base offset in scientific notation. Command format :TIMebase[:MAIN]:SCALe :TIMebase[:MAIN]:SCALe? Function description Set or query the main time base scale. The default unit is s / div.

Parameter Name Type Range Default Integer YT mode: 5ns / div to 50s / div, 1-2-5 steps Roll mode: 200ms / div to 50s / div, 1-2-5 steps 1μs/div Description When the horizontal time base mode is YT and the horizontal time base is 200ms / div or greater (that is, "slow scan" mode), this command is not available during the oscilloscope stop. Return format The query returns the main time base scale in scientific notation. Command format :TIMebase:MODE :TIMebase:MODE? Function description Sets or queries the horizontal time base mode. Parameter Name Type Range Default Discrete {MAIN|XY|ROLL} MAIN Description MAIN: YT mode XY: XY mode ROLL:

Roll mode Return format The query returns MAIN, XY, or ROLL.