Delta DVP — 4.3.1 Connectable Left-side Extension Module

DVP-15MC Series Motion Controller Operation Manual 4.1 System Constitution A multi-layer industrial network can be built by means of the motion controller. By using the motion controller, the network can consist of top-layer Ethernet, middle-layer CANopen and Profibus bus as well as bottom- layer RS-485 bus which supports Modbus as follows. 4 The figure above illustrates the peripheral devices which are connected to various ports of the motion controller in the entire system. Refer to chapter 6 for details on the functions of communication ports. 4.2 Power Supply Delta power modules are recommended as the power supply for the motion controller.

The information of Delta power modules is shown in the following table. 4.3 Left-side Extension 4.3.1 Connectable Left-side Extension Module Max. 8 high-speed extension modules can be connected to the left side of the motion controller and the connectable modules are listed in the following table. 4-2 No. Module Phase Input Output Power Output International name voltage voltage current Standard 1 DVPPS02 Single phase 85~264VAC 24VDC 48W 2A 2 DVPPS05 120W 5A No. Module name Module type Description 1 DVP04AD-SL Analog module Analog input