2. Programming Concepts 2-21 OFF STOP RUN Special ES2 SA2 Latch Function SS2 SX2 Attrib.
Default M EX2 SE -ed ON RUN STOP M1422* Indicate that reading from Slave ID#15 is completed ○ ○ ○ ○ OFF - - R NO OFF M1423* Indicate that reading from Slave ID#16 is completed ○ ○ ○ ○ OFF - - R NO OFF M1424* Indicate that writing to Slave ID#1 is completed ○ ○ ○ ○ OFF - - R NO OFF M1425* Indicate that writing to Slave ID#2 is completed ○ ○ ○ ○ OFF - - R NO OFF M1426* Indicate that writing to Slave ID#3 is completed ○ ○ ○ ○ OFF - - R NO OFF M1427* Indicate that writing to Slave ID#4 is completed ○ ○ ○ ○ OFF - - R NO OFF M1428* Indicate that writing to Slave ID#5 is completed ○ ○ ○ ○ OFF - - R NO OFF M1429* Indicate that writing to Slave ID#6 is completed ○ ○ ○ ○ OFF - - R NO OFF M1430* Indicate that writing to Slave ID#7 is completed ○ ○ ○ ○ OFF - - R NO OFF M1431* Indicate that writing to Slave ID#8 is completed ○ ○ ○ ○ OFF - - R NO OFF M1432* Indicate that writing to Slave ID#9 is completed ○ ○ ○ ○ OFF - - R NO OFF M1433* Indicate that writing to Slave ID#10 is completed ○ ○ ○ ○ OFF - - R NO OFF M1434* Indicate that writing to Slave ID#11 is completed ○ ○ ○ ○ OFF - - R NO OFF M1435* Indicate that writing to Slave ID#12 is completed ○ ○ ○ ○ OFF - - R NO OFF M1436* Indicate that writing to Slave ID#13 is completed ○ ○ ○ ○ OFF - - R NO OFF M1437* Indicate that writing to Slave ID#14 is completed ○ ○ ○ ○ OFF - - R NO OFF M1438* Indicate that writing to Slave ID#15 is completed ○ ○ ○ ○ OFF - - R NO OFF M1439* Indicate that writing to Slave ID#16 is completed ○ ○ ○ ○ OFF - - R NO OFF M1524 Auto-reset Y2 when high speed pulse output is completed ○ ○ ○ ○ OFF - - R/W NO OFF M1525 Auto-reset Y3 when high speed pulse output is completed ○ ○ ○ ○ OFF - - R/W NO OFF M1534 Enable ramp-down time setting on Y0.
Has to be used with D1348. ○ ○ ○ ○ OFF - - R/W NO OFF M1535 Enable ramp-down time setting on Y2. Has to be used with D1349. ○ ○ ○ ○ OFF - - R/W NO OFF M1538 Indicate pause status of Y0 ○ ○ ○ ○ OFF OFF - R/W NO OFF M1539 Indicate pause status of Y1 ○ ○ ○ ○ OFF OFF - R/W NO OFF M1540 Indicate pause status of Y2 ○ ○ ○ ○ OFF OFF - R/W NO OFF M1541 Indicate pause status of Y3 ○ ○ ○ ○ OFF OFF - R/W NO OFF M1580 The absolute position of Delta ASDA-A2 servo is read successfully by means of the instruction DABSR. V3.2 ╳ V2.6 V1.4 V2.4 OFF OFF OFF R/W NO OFF M1581 The absolute position of Delta ASDA-A2 servo is not read successfully by means of the instruction DABSR.
V3.2 ╳ V2.6 V1.4 V2.4 OFF OFF OFF R/W NO OFF M1584 If the left limit switch of CH0 is enabled, it can be triggered either by a rising-edge signal or by a falling-edge signal. (OFF: Rising-edge signal; ON: Falling-edge signal) V3.2 V3.0 V2.8 V1.4 V2.6 OFF OFF - R/W NO OFF M1585 If the left limit switch of CH1 is enabled, it can be triggered either by a rising-edge signal or by a falling-edge signal. (OFF: Rising-edge signal; ON: Falling-edge signal) V3.2 V3.0 V2.8 V1.4 V2.6 OFF OFF - R/W NO OFF