Delta DVP-ES3 — 2.2.7 Special Auxiliary Relays (SM)

DVP-ES3 Series Programming Manual _2 2-16 Latched Attribute Default OFF STOP RUN SM Function    ON RUN STOP *SM403 The flag is OFF only at the first scan.

OFF OFF ON N R OFF *SM404 10 millisecond clock pulse during which the pulse is ON for 5 milliseconds and then OFF for 5 milliseconds OFF – – N R OFF *SM405 100 millisecond clock pulse during which the pulse is ON for 50 milliseconds and then OFF for 50 milliseconds OFF – – N R OFF *SM406 200 millisecond clock pulse during which the pulse is ON for 100 milliseconds and then OFF for 100 milliseconds OFF – – N R OFF *SM407 One second clock pulse during which the pulse is ON for 500 milliseconds and then OFF for 500 milliseconds OFF – – N R OFF *SM450 Memory card is present ON: the memory card is present. OFF: the memory card is not present.

– – – N R OFF *SM452 The data in the memory card is being accessed. ON: the data in the memory card is being accessed. OFF: the data in the memory card is not accessed. OFF – – N R OFF *SM453 Error during the operation of the memory card. ON: an error occurs. OFF: no error. OFF – – N R OFF SM454 Enabling/disabling the data logger. ON: enable OFF: disable OFF – – N R/W OFF SM455 The data logger is currently taking samples. ON: number of records has reached its sampling limit OFF – – N R OFF *SM456 Execution of data logger and the memory card. ON: execution by the values in SR902. OFF – – N R/W OFF SM457 State of the sample parameters in data logger ON: the sample parameter is set.

– – – N R OFF SM460 Outputting Y0/axis 1 (Y0/Y1). OFF OFF – N R OFF SM461 Y0/axis 1 (Y0/Y1) output is complete. OFF OFF – N R/W OFF SM462 Reversing the output direction of axis 1 (Y1) OFF OFF – N R/W OFF *SM463 Stopping the output of Y0/axis 1 (Y0/Y1) OFF OFF – N R/W OFF SM464 Enabling the positive maximum value for axis 1 (Y0/Y1) – – – Y R/W OFF SM465 Alarm: positive limit for axis 1 (Y0/Y1) OFF OFF – N R/W OFF SM466 Enabling the negative maximum value for axis 1 (Y0/Y1) – – – Y R/W OFF SM467 Alarm:

negative limit for axis 1 (Y0/Y1) OFF OFF – N R/W OFF *SM468 Enabling the S curve ramp-up/down for axis 1 (Y0/Y1) OFF OFF – N R/W OFF SM469 Enabling fixed slope ramp-up/down for axis 1 (Y0/Y1) OFF OFF – N R/W OFF SM470 Auto-reset for Y0/axis 1 (Y0/Y1) output is complete. OFF OFF – N R/W OFF SM471 Executing an interrupt I500 when pulse output ends for axis 1 (Y0/Y1) OFF OFF – N R/W OFF SM472 Outputting Y1. OFF OFF – N R OFF SM473 Y1 output is complete. OFF OFF – N R/W OFF *SM474 Stopping the output of Y1. OFF OFF – N R/W OFF