DVP-ES3 Series Programming Manual Symbol S 1 : Timer number S 2 : Setting value for the timer Explanation This instruction uses 10ms as the unit of time. _6 Refer to the explanation of the TMRH instruction (API 1002) for details. 6-300 API Instruction code Operand Function 1011 TMRM S1, S2 16-bit timer (10ms) Device X Y M S T C HC D FR SM SR E K 16# “$” F S1 S2 BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S1 S2 Pulse instruction 16-bit instruction 32-bit instruction - ES3 -