DVP-ES3 Series Programming Manual _2 2-44 Special auxiliary Refresh time relay SM1130 ON: the trigger is enabled and the last mail has been sent with an error. SM1132 ON: the trigger is enabled and there is an SMTP server response timeout. SM1133 ON: the trigger is enabled and there is an SMTP server response error. SM1134 ON: the trigger is enabled and the size of the attachment exceeds the limit. SM1135 ON: the trigger is enabled and the attachment is not found. SM1136 ON: the trigger for the PLC parameter is enabled. SM1137 ON: the trigger for the PLC parameter is triggered. SM1139 ON: the trigger is enabled and the last mail has been sent successfully. SM1140 ON:
the trigger is enabled and the last mail has been sent with an error. SM1142 ON: the trigger is enabled and there is an SMTP server response timeout. SM1143 ON: the trigger is enabled and there is an SMTP server response error. SM1144 ON: the trigger is enabled and the size of the attachment exceeds the limit. SM1145 ON: the trigger is enabled and the attachment is not found. SM1146 ON: the trigger for the PLC parameter is enabled. SM1147 ON: the trigger for the PLC parameter is triggered. SM1149 ON: the trigger is enabled and the last mail has been sent successfully. SM1150 ON: the trigger is enabled and the last mail has been sent with an error. SM1152 ON:
the trigger is enabled and there is an SMTP server response timeout. SM1153 ON: the trigger is enabled and there is an SMTP server response error. SM1154 ON: the trigger is enabled and the size of the attachment exceeds the limit. SM1155 ON: the trigger is enabled and the attachment is not found. SM1166 After the data exchange parameters are downloaded, the system is refreshed. SM1167–SM1183 After the data exchange parameters are downloaded, you set the flag to ON or OFF. SM1200–SM1215 SM1232–SM1247 ON: when the system is refreshed. SM1269 ON: there is a socket configuration error. SM1270–SM1353 The flag is refreshed when the socket function is executed. SM1440–SM1447 ON:
a timeout occurred in the adapter of the I/O connection through EtherNet/IP. SM1448~SM1455 ON: I/O connection is established through EtherNet/IP (Adapter). OFF: I/O connection is NOT established through EtherNet/IP (Adapter) or the communication is disconnected. SM1581–SM1588 You set the flag to ON or OFF. SM1601–SM1608 You set the flag to ON or OFF. SM1611-SM1618 The system sets the flag to ON or OFF. SM1621-SM1628 The system sets the flag to ON or OFF. SM1631–SM1638 The system sets the flag to ON and you set it to OFF. SM1641–SM1648 You set the flag to ON or OFF. SM1651–SM1658 The system sets the flag to ON or OFF. SM1661–SM1668 You set the flag to ON or OFF.
SM1671–SM1682 The system sets the flag to ON or OFF. SM1683 The system sets the flag to ON or OFF. SM1684—SM1685 You set the flag to ON or OFF. SM1691-SM1698 The system sets the flag to ON or OFF.