Delta DVP-ES3 — 6.17.2 Explanation of Real-time Clock Instructions

Chapter 6 Applied Instructions 6_ Symbol S : Daylight saving time function codes S 1 : Month of the daylight saving start time S 2 : Date of the daylight saving start time S 3 : Month of the daylight saving end time S 4 : Date of the daylight saving end time S 5 : Change due to daylight saving time (minutes) D : The state of the daylight saving function 6-493 API Instruction code Operand Function 1607 DST P S, S1, S2, S3, S4, S5, D Daylight saving time Device X Y M S T C HC D FR SM SR E K 16# “$” F S      S1      S2      S3      S4      S5      D     BOOL WORD DWORD LWORD UINT INT DINT LINT REAL LREAL TMR CNT STRING Data type S    S1    S2    S3    S4    S5    D  Pulse instruction 16-bit instruction 32-bit instruction ES3 ES3 -