Delta DVP-ES3 — 6.19.2 Explanation of Communication Instructions

DVP-ES3 Series Programming Manual 5. The following chart shows the timing for sending and receiving data. Enable/disable t he execution of the instruction _6 Sending data Reception fl ag Receiving data   Description: Compl etion fl ag  Start or stop the execution of the instruction.  Transmitting data begins. During this period, the communication timeout time is not measured.  The reception flag is set. From the moment when the first character is received to the moment when the next character is received, the period of time is measured. Whenever a character is received, the measured is cleared to 0.

The instruction generates the communication timeout flag if the time measured is greater than 6-574 stop 4999 (run clockwise) 4998 (run counterclockwise) 0 (stop) 20 Servo ON/OFF 1: Servo On Any other value: Servo OFF Writing the data into the registers P2-30 21 Velocity command (3 sets) Occupies 6 consecutive devices with the valid setting value range: -60000 to 60000 Writing data into the registers P1-09–P1-11 (32-bit value) 22 Torque command (3 sets) Occupies 6 consecutive devices with the valid setting value range:

-300 to 300 Writing the data into the registers P1-12–P1-14 (32-bit value) 23 Setting the mapping targets of servo parameters Occupies 8 consecutive devices S–S+7 Writing the data into the registers P0-35–P0-38 (32-bit value) *1: B2 series does not support function code 18 and 23.        