Delta DVP — 3.14 Performing Teaching Function with Normal Timer

3. Timer Design Examples 3.14 Performing Teaching Function with Normal Timer X2 X3 X0 X1 Teach Start Manual Auto Control Purpose: z In Manual mode, the engineers should adjust stamping time according to their experience. The stamping time depends on the time of pressing Teach. z In Auto mode, if Start is pressed, the machine will perform stamping process once according to the time value saved by Teach process. Devices: DVP-PLC Application Examples 3-23 Device Function X0 Teach Button. X0 = ON when the button Teach is pressed. X1 Start button. X1 = ON when the button Start is pressed. X2 Manual mode X3 Auto mode M1 Start trigger in auto mode T0 Timer. Time base: 100ms T1 Timer. Time base:

100ms D0 Data register. Saving the time value of stamping Y0 Starting the punch when Teach is pressed Y1 Starting the punch when Start is pressed in Auto mode