Mitsubishi — 3.2 Explanations on Basic Instructions

3 Basic Instructions Explanations: ANDF instruction is used in the series connection of the contacts’ falling-edge detection. Program Example: Ladder diagram: Instruction code: Operation: LD X0 Loading in A contact of X0 X0 OUT Y1 Drive Y1 coil Explanations: The ORP instructions are used in the parallel connection of the contact’s rising-edge detection. Program Example: Ladder diagram: Instruction code: Operation: X0 LD X0 Loading in A contact of X0 X1 Y1 OUT Y1 Driving Y1 coil Explanations: The ORP instructions are used in the parallel connection of the contact’s falling-edge detection.

DVP-PLC Application Manual 3-14 Mnemonic Function Program steps 1 Controllers ES EX SS SA SX SC EH2 SV EH3 SV2 ANDF Falling-edge series connection Operand X0 ~ X377 Y0 ~ Y377 M0 ~ M4095 S0 ~ S1023 T0 ~ T255 C0 ~ C255 D0 ~ D9999       - Controllers ES EX SS SA SX SC EH2 SV EH3 SV2 X1 Y1 ANDF X1 X1 falling-edge detection in series connection Mnemonic Function Program steps 1 Controllers ES EX SS SA SX SC EH2 SV EH3 SV2 ORP Rising-edge parallel connection X0 ~ X377 Y0 ~ Y377 M0 ~ M4095 S0 ~ S1023 T0 ~ T255 C0 ~ C255 D0 ~ D9999 Operand       - Controllers ES EX SS SA SX SC EH2 SV EH3 SV2 ORP X1 X1 rising-edge detection in parallel connection Mnemonic Function Program steps Controllers ES EX SS SA SX SC EH2 SV EH3 SV2 ORF Falling-edge parallel connection 1 X0 ~ X377 Y0 ~ Y377 M0 ~ M4095 S0 ~ S1023 T0 ~ T255 C0 ~ C255 D0 ~ D9999 Operand       - Controllers ES EX SS SA SX SC EH2 SV EH3 SV2