Mitsubishi — Chapter 7 Application Instructions API 50-88

7 Application Instructions API 50-99 Operands: S : Source device to be decoded D : Output device after the decoding Explanations: See the specifications of each model for their range of use. Program Example: When X10 = On, the contents (0 ~ F in hex) of the lower 4 bits (b0 ~ b3) of D10 will be decoded into a 7-segment display for output. The decoded results will be stored in Y10 ~ Y17. If the content exceeds 4 bits, the lower 4 bits are still used for the decoding. X10 Decoding table of the 7-segment display:

DVP-PLC APPLICATION MANUAL 7-81 API Mnemonic Operands Function 73 SEGD P Seven Segment Decoder Type OP Bit Devices Word Devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F SEGD, SEGDP:

5 steps S * * * * * * * * * * * D * * * * * * * * PULSE 16-bit 32-bit EH3 EH3 ES EX SS SA SX SC EH SV EH3 SV2 S EX SS SA S X SC EH SV ES EX SS SA SX SC EH SV SV2 SV2 SEGD D10 K2Y10 Hex Bit combi- nation Composition of the 7- segment display Status of each segment Data displayed 0 0000 a g b c d ON O N ON ON ON ON OFF 1 0001 OFF O N ON OFF OFF OFF OFF 2 0010 ON O N OFF ON ON OFF ON 3 0011 ON O N ON ON OFF OFF ON 4 0100 OFF O N ON OFF OFF ON ON 5 0101 ON O FF ON ON OFF ON ON 6 0110 ON O FF ON ON ON ON ON 7 0111 ON O N ON OFF OFF ON OFF 8 1000 ON O N ON ON ON ON ON 9 1001 ON O N ON ON OFF ON ON A 1010 ON O N ON OFF ON ON ON B 1011 OFF O FF ON ON ON ON ON C 1100 ON O FF OFF ON ON ON OFF D 1101 OFF O N ON ON ON OFF ON E 1110 ON O FF OFF ON ON ON ON F 1111 ON O FF OFF OFF ON ON ON