Mitsubishi — Chapter 8 Application Instructions API 100-149

9 Application Instructions API 150-199 Use absolute positioning instruction to travel to absolute position 500,000 (Y1=On). Use absolute positioning instruction to travel to absolute position 00 (Y1=On). 1 12. Flags and special registers for SC series MPU: M1347: For SC (V1.6 and later versions). Auto reset after Y0 output is completed. M1348: For SC (V1.6 and later versions). Auto reset after Y1 output is completed. M1524: For SC (V1.6 and later versions). Auto reset after Y10 output is completed. M1525: For SC (V1.6 and later versions). Auto reset after Y11 output is completed. 13. Flags and special registers for EH/EH2/SV/EH3/SV2 series MPU: M1347:

For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH0 pulse output. M1348: For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH1 pulse output. M1524: For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH2 pulse output. M1525: For EH2/SV/EH3/SV2 (V1.4 and later versions). Reset flag for CH3 pulse output.

DVP-PLC Application Manual 9-67 S23 S DDRVA K500000 K100000 Y0 Y1 Forward positioning Absolute Output pulse Pulse outputOutput point position frequency device reverse sign M1029 M3 SET M12 Forward positioning complete Execution completed M1336 M3 S0 Forward positioning is completed Y0 output being executed M1000 M3 Time-out 1 scan period S24 U S DDRVA K100 K100000 Y0 Y1 t Backward positioning Absolute Output pulse Pulse outputOutput point for position frequency device reverse signals M1029 M4 SET M13 Backward positioning complet Execution completed M1336 M3 S0 Backward positioning is completed M1000 M3 Time-out 1 scan period RET END END DDRVA K500000 K100000 Y0 Y1 SET M12 DDRVA K100 K100000 Y0 Y1 SET M13