2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-39 ES SA Off STOP RUN Special EH2 EH3 Function EX SX Attribute Latched Default M SV SV2 SS SC On RUN STOP M1029* ES/SA: Y0 pulse output of PLSY, PLSR instructions is completed, or other relevant instructions complete their executions. EH2/SV/EH3/SV2: the 1st group pulse output CH0 (Y0, Y1) is completed, or other relevant instructions complete their executions. ○ ○ ○ ○ Off - - R NO Off M1030* ES/SA: Y1 pulse output of PLSY, PLSR instructions is completed, or other relevant instructions complete their executions. EH2/SV/EH3/SV2:
the 2nd group pulse output CH1 (Y2, Y3) is completed, or other relevant instructions complete their executions. ○ ○ ○ ○ Off - - R NO Off M1031* Clear all non-latched areas ○ ○ ○ ○ Off - - R/W NO Off M1032* Clear all latched areas ○ ○ ○ ○ Off - - R/W NO Off M1033* Memory latched when STOP ○ ○ ○ ○ Off - - R/W NO Off M1034* Disabling all Y outputs ○ ○ ○ ○ Off - - R/W NO Off M1035* Enabling input point X as the RUN/STOP switch, corresponding to D1035 (SA designates X7 only; SX designates X3 only; SC designates X5 only) ╳ ○ ○ ○ - - - R/W YES Off M1036* EH2/SV/EH3/SV2: the 3rd group pulse output CH2 (Y4, Y5) is completed.
(Not available in EH) ╳ ╳ ○ ○ Off - - R NO Off SPD instruction is able to use X0 ~ X5 to detect the flag (only available in SC V1.4 and _ versions above) ╳ ○ ╳ ╳ Off Off - R/W NO Off M1037 EH2/SV/EH3/SV2: the 4th group pulse output CH3 (Y6, Y7) is completed. (Not available in EH) ╳ ╳ ○ ○ Off - - R NO Off M1038 Off: The time base of T0~T99 is 100ms. On: The time base of T0~T99 is 1ms.
╳ ╳ ╳ ○ Off - - R/W NO Off M1039* Fixing time scan mode ○ ○ ○ ○ Off - - R/W NO Off M1040 Disabling step ○ ○ ○ ○ Off - - R/W NO Off M1041 Starting step ○ ○ ○ ○ Off - Off R/W NO Off M1042 Enabling pulses ○ ○ ○ ○ Off - - R/W NO Off M1043 Zero return completed ○ ○ ○ ○ Off - Off R/W NO Off M1044 Zero point condition ○ ○ ○ ○ Off - Off R/W NO Off M1045 Disabling all output reset ○ ○ ○ ○ Off - - R/W NO Off M1046 Setting STL status as On ○ ○ ○ ○ Off - - R NO Off M1047 Enabling STL monitoring ╳ ○ ○ ○ Off - - R/W NO Off M1048 Alarm status ╳ ○ ○ ○ Off - - R NO Off M1049 Setting up alarm monitoring ╳ ○ ○ ○ Off - - R/W NO Off M1050 Inhibiting I001 ○ ○ ╳ ╳ Off - - R/W NO Off M1051 Inhibiting I101 ○ ○ ╳ ╳ Off - - R/W NO Off M1052 Inhibiting I201 ○ ○ ╳ ╳ Off - - R/W NO Off M1053 Inhibiting I301 ○ ○ ╳ ╳ Off - - R/W NO Off Enabling X4 speed detection ╳ ╳ ○ ○ Off Off Off R/W NO Off M1054 Inhibiting I401 ╳ ○ ╳ ╳ Off - - R/W NO Off Enabling X10 speed detection ╳ ╳ ○ ○ Off Off Off R/W NO Off M1055 Inhibiting I501 ╳ ○ ╳ ╳ Off - - R/W NO Off Enabling X14 speed detection ╳ ╳ ○ ○ Off Off Off R/W NO Off M1056 Inhibiting I6□□ ○ ○ ╳ ╳ Off - - R/W NO Off Enabling X1 interrupt to get the counting value of C241 ╳ ╳ ╳ ○ Off Off Off R/W NO Off M1057 Inhibiting I7□□ ╳ ○ ╳ ╳ Off - - R/W NO Off Enabling X2 interrupt to get the counting value of C241 ╳ ╳ ╳ ○ Off Off Off R/W NO Off M1058 COM3 monitoring request ╳ ╳ ╳ ○ Off - - R/W NO Off M1059 Inhibiting I010 ~ I060 ╳ ○ ╳ ╳ Off - - R/W NO Off Enabling X3 interrupt to get the counting value of C241 ╳ ╳ ╳ ○ Off Off Off R/W NO Off