9 Application Instructions API 150-199 M1542: CH0 executes the function that the constant speed output section reaches the target frequency. M1544: CH1 executes the function that the constant speed output section reaches the target frequency. M1546: CH2 executes the function that the constant speed output section reaches the target frequency. M1548: CH3 executes the function that the constant speed output section reaches the target frequency. M1543: CH0 executed the function that the constant speed output section reaches the M1545: CH1 executed the function that the constant speed output section reaches the target number. target number. M1547:
CH2 executed the function that the constant speed output section reaches the target number. M1549: CH3 executed the function that the constant speed output section reaches the target number. M1528: Enabling the instruction DICF to execute the constant speed output section M1529: Enabling the instruction DICF to execute the final output section 2. Special register explanations: DVP-PLC Application Manual 9-143 D1336: Low word of the present value of Y2 pulse output D1337: High word of the present value of Y2 pulse output D1338: Low word of the current number of output pulses from CH1 D1339: High word of the current number of output pulses from CH1 D1375:
Low word of the current number of output pulses from CH2 D1376: High word of the current number of output pulses from CH2 D1377: Low word of the current number of output pulses from CH3 D1378: High word of the current number of output pulses from CH3