Mitsubishi — Chapter 10 Application Instructions API 202-313

10 Application Instructions API 202-313 Operands: S : Reference source device n : Reference bit Explanations: 1. EH2/SV_V1.9 and versions above, and EH3/SV2 supports the function. EH series does not support the dunction. 2. Available range for the value in operand n : K0~K15 for 16-bit instruction; K0~K31 for 32-bit instruction. 3. BLD instruction is used to load NC contact whose contact state is defined by the reference bit n in reference device D , i.e. if the bit specified by n is ON, the NC contact will be ON, and vice versa. Program Example: Y0 Instruction: Operation:

BLDI D0 K1 Load NC contact with bit status of bit1 in D0 OUT Y0 Drive coil Y0 DVP-PLC Application Manual 10-25 API Mnemonic Operands Function 270 D BLDI Load NC Contact by Specified Bit Type OP Bit Devices Word devices Program Steps X Y M S K H KnX KnY KnM KnS T C D E F BLDI: 5 steps DBLDI: 9 steps S * * * * * * n * * * * * * * * * * * PULSE 16-bit 32-bit SA SX SC EH SV EH3 SV2 ES EX SS SA SX SC EH3 ES EX SS SA SX SC EH3 ES EX SS EH SV EH SV SV2 SV2 BLDI D0 K1