Mitsubishi — 2.10 Special Auxiliary Relays and Special Data Registers

2 Functions of Devices in DVP-PLC DVP-PLC Application Manual 2-53 ES SA Off STOP RUN Special EH2 EH3 Function EX SX    Attribute Latched Default M SV SV2 SS SC On RUN STOP M1508* Indicating writing to Salve ID#21 is completed ╳ ╳ ○ ○ Off - - R NO Off M1509* Indicating writing to Salve ID#22 is completed ╳ ╳ ○ ○ Off - - R NO Off M1510* Indicating writing to Salve ID#23 is completed ╳ ╳ ○ ○ Off - - R NO Off M1511* Indicating writing to Salve ID#24 is completed ╳ ╳ ○ ○ Off - - R NO Off M1512* Indicating writing to Salve ID#25 is completed ╳ ╳ ○ ○ Off - - R NO Off M1513* Indicating writing to Salve ID#26 is completed ╳ ╳ ○ ○ Off - - R NO Off M1514* Indicating writing to Salve ID#27 is completed ╳ ╳ ○ ○ Off - - R NO Off M1515* Indicating writing to Salve ID#28 is completed ╳ ╳ ○ ○ Off - - R NO Off M1516* Indicating writing to Salve ID#29 is completed ╳ ╳ ○ ○ Off - - R NO Off M1517* Indicating writing to Salve ID#30 is completed ╳ ╳ ○ ○ Off - - R NO Off M1518* Indicating writing to Salve ID#31 is completed ╳ ╳ ○ ○ Off - - R NO Off M1519* Indicating writing to Salve ID#32 is completed ╳ ╳ ○ ○ Off - - R NO Off M1520 EH2/SV/EH3/SV2:

stopping the 3rd group pulse output CH2 (Y4, Y5) (Not available in EH) ╳ ╳ ○ ○ Off - - R/W NO Off M1521 EH2/SV/EH3/SV2: stopping the 4th group pulse output CH3 (Y6, Y7) (Not available in EH) ╳ ╳ ○ ○ Off - - R/W NO Off M1522 EH2/SV/EH3/SV2: sending out the 3rd group pulse output CH2 (Y4, Y5) (Not available in EH) ╳ ╳ ○ ○ Off - Off R NO Off M1523 EH2/SV/EH3/SV2: sending out the 4th group pulse output CH3 (Y6, Y7) (Not available in EH) ╳ ╳ ○ ○ Off - Off R NO Off M1524 EH2/SV/EH3/SV2: reset after the 3rd group pulse output CH2 (Y4, Y5) is completed (Not available in EH) SC: reset after Y10 high-speed pulse output is completed ╳ ○ ○ ○ Off - - R/W NO Off M1525 EH2/SV/EH3/SV2:

reset after the 4th group pulse output CH3 (Y6, Y7) is completed (Not available in EH) SC: reset after Y11 high-speed pulse output is completed ╳ ○ ○ ○ Off - - R/W NO Off M1526 EH2/SV/EH3/SV2: reversing Y4 pulse output signal for PWM instruction (Not available in EH) ╳ ╳ ○ ○ Off - - R/W NO Off M1527 EH2/SV/EH3/SV2: reversing Y6 pulse output signal for PWM instruction (Not available in EH) ╳ ╳ ○ ○ Off - - R/W NO Off M1528* Enabling the instruction DICF to execute the constant speed output section ╳ ╳ ╳ ○ Off Off Off R/W NO Off M1529* Enabling the instruction DICF to execute the final output section ╳ ╳ ╳ ○ Off Off Off R/W NO Off M1530 EH2/SV/EH3/SV2:

switching time base unit of Y4 output for PWM instruction On: 100us; Off: 1ms (Not available in EH) ╳ ╳ ○ ○ Off - - R/W NO Off M1531 EH2/SV/EH3/SV2: switching time base unit of Y6 output for PWM instruction On: 100us; Off: 1ms (Not available in EH) ╳ ╳ ○ ○ Off - - R/W NO Off M1532 EH2/SV/EH3/SV2: reverse operation of the 3rd group pulse CH2 (Y4, Y5) for PLSV/DPLSV/DRVI/DDRVI/DRVA /DDRVA instruction (Not available in EH) ╳ ╳ ○ ○ Off - - R/W NO Off M1533 EH2/SV/EH3/SV2: reverse operation of the 4th group pulse CH3 (Y6, Y7) for PLSV/DPLSV/DRVI/DDRVI/DRVA /DDRVA instruction ╳ ╳ ○ ○ Off - - R/W NO Off M1534 EH2/SV/EH3/SV2: CH0 being able to designate deceleration time. Has to be used with D1348.

╳ ╳ ○ ○ Off - - R/W NO Off M1535 EH2/SV/EH3/SV2: CH1 being able to designate deceleration time. Has to be used with D1349. ╳ ╳ ○ ○ Off - - R/W NO Off