DVS-108 Series Managed Industrial Ethernet Switches User Manual Versions 3.1.2 Network Interface The network interface on the network device is a logical interface. Each network device must have one or more interfaces to connect with other network devices. But the configuration of the network interface doesn’t affect the traffic which is forwarded. 3.1.2.1 IPv4 Network Configuration You can configure a static IP address, subnet mask and default gateway for the switch. Or you can enable DHCP or BOOTP for receiving a dynamic IP address, subnet mask and default gateway.
If you enable DHCP or BOOTP, but there is no DHCP or BOOTP server in the network, the default link local IP address will be 169.254.100.100. Note: The default Current Network Configuration Protocol is None. And the default IP address is 192.168.1.5. 3-6 Description Factory Default System Up Time The time of hours, minutes, and seconds since the switch was last started. None Base MAC Address The MAC address of the switch. Fixed Description Factory Default Model Name The model name of the switch. Model Name Boot Version The boot version of the switch. Boot Version Software Version The software version of the switch. Software Version