4 - 2 System Specifications This section describes the system specifications of this project. Monitorable range on the screen. * 1: When multiple Communication Units are connected, a program of the project file needs to be changed. Monitorable and settable items on the screen. * 1: ”Setting all” can be set on dedicated screens. * 2: Setting can be changed with [+][-]key or numeric keypad. Pop-up for EtherCAT NODE switching Pop-up for language switching Detailed settings screen (setting all/ individual setting) 12 Target Model Remarks CPU NJ-series HMI NA5-series 7,9,12,15 inch supported. Communication Unit E3NW-ECT Possible to use E3NW-DC (Distributed Unit).
Sensor amplifier E3NX-FA Fiber Amplifier E3NC-LA Laser Amplifier E3NC-SA Laser Amplifier (CMOS) E3NC-TA Contact Amplifier Applicable sensor head E32 -series Applicable sensor head E3NC-LH -series Applicable sensor head E3NC-SH -series Applicable sensor head E9NC-TH -series Function Monitorable range Remarks No. of nodes 1 to 192 The specified 1 node is displayed. Node 100 is used in this project file. To monitor, enter a node No. to be monitored.*1 The variables for 2 nodes such as node 100 and 101 are registered in this project file. No. of Units 1 to 24 sensor amplifiers can be connected. Unit No.25 to 30 cannot be allocated in this project file.
There is no restriction on the connected position of each sensor amplifier.
Function Input port Target Model name of connected sensor amplifier for each unit - - Flashing function 1 / 2 - Input port ON/OFF status monitor 1 / 2 - Input port Light ON / Dark ON operation setting monitor/ setting 1 / 2 *1 Smart tuning function 1 / 2 Setting all/ individual setting Threshold (SV value) monitor/ setting *2 1 / 2 *1 Incident light (PV value) monitor 1 - ST DPC status monitor - - Sensor detail setting 1 / 2 Setting all/ individual setting Trend graph and change recording log (latest 30 logs) 1 - For setting all, select all/clear all of sensor amplifiers - - For setting all, individual select/individual clear of sensor amplifier - - Function Remarks Switches a node No.
to be monitored. (a numeric keypad is used to change setting) Displays a list of node No. connected in the system ( up to 21 nodes). Function Remarks Switches a display language. Japanese, English, Chinese (Simplified), and Korean are supported. Function Remarks Sets each function to the selected sensor amplifier. The screen of “individual setting” shows the current settings (each button lamp turns on). The screen of “setting all” turns on each lamp button only when the corresponding function is selected.