6 - 7 Detailed Setting Screen 3 This screen allows you to display the current values of the percent/ power tuning settings and connecting head, and to change these settings. It also sets the percent, power tuning level, hysteresis width, and executes the DPC function, keep setting, background removal. Additional Information The example screen above shows all the function buttons that can be set on the screen. In actual operation, function buttons unsettable by the connected sensor amplifiers are not displayed on the screen. In the “ Object ” column above, B stands for Button, L for Lamp, and BL for Button Lamp.
34 Function Object Description > button B Moves to the Detailed Settings Screen 4 (Detailed Settings Screen 1 for certain model of amplifiers). B Moves to the Detailed Settings Screen 2 (Detailed Settings Screen 1 for certain model of amplifiers). “Return” button B Return to the Monitor screen. Power tuning setting BL Displays the status of current setting. The indicator in blue indicates the current setting. If a lights-off button is pressed, the setting changes, and the changed button will light blue. Percent tuning setting BL Connecting head BL DPC function B Executes each operation. This instruction cannot indicate the status (i.e. lightning in blue).
Keep setting B Background removal B Power tuning level - Displays the value of current setting. You can change the set value using a numeric keypad that is displayed by clicking in the numerical display area. Percent tuning level - Hysteresis width setting - Hysteresis width IN1 - Hysteresis width IN2 -