E556GB — 5.3.3.1 Program structure

KUBES modules 5.3.3 Reading data (RD_OFFS) KUBES module: RD_OFFS Length: 58 byte Processing time: c. 89 µ s Function: read operand data First address Operand range FBM00.00...01 0 1 2 Offset: BM01.00 3 4 0+Offset BM00.03 Data BM00.02 0+Offset+1 . . . n Fig. 12: KUBES module "RD_OFFS" 5.3.3.1 Program structure Ш Specify the first address of the source operand range for reading [FBM00.00...01] з Ш Set the offset of an address in the range (0 = first) [BM01.00] з Ш Start KUBES module RD_OFFS Ш Evaluate 1 or 2 byte of data [BM00.02...03] и Example program ( а 5.3.5) 85