sinee — 3.2.1 Main circuit (high voltage part) terminals description

EA180 Series Servo Drive Users Manual and 24V power supply, especially when power is supplied to several servo drives or brakes at the same time. Insufficient power supply capacity will lead to insufficient supply current, which may cause damage to the servo drives or brakes. 4) Please note that the brake power supply is 24V DC, and its capacity shall meet the power requirements of the brake. For braking power, please refer to the servo motor description. 5) Confirm correct phase sequence and wiring of the U, V and W output terminals of the servo motor. Wrong wiring may cause the motor to fail to run or run disorderly, thus causing alarm and even motor damage.

6) When an external braking resistor is used, the P+ and D terminals shall be open-circuited, and the resistor shall be connected to the P+ and C terminals. If an internal braking resistor is used, the P+ and D terminals shall be short-circuited and the P+ and C terminals shall be open-circuited (refer to Section 2.7). 7) In single-phase 220V wiring, the main power supply terminals are L1 and L2. If there is an L3 terminal, please do not wire on it. 8) CN2 and CN3 are two communication interfaces with exactly the same definition of pins, and you can use either of them.

3.2 Main circuit terminal connection The terminal arrangement and screw size of the main circuit (high voltage part) are as follows.

3.2.1 Main circuit (high voltage part) terminals description Table 3-1 Description of main circuit terminals of servo drive 20 SIZE A SIZE B SIZE C SIZE D Main circuit terminals Drive size Screw size Torque SIZE A N/A - SIZE B N/A - SIZE C M4 2.5 N.m SIZE D M4 2.5 N.m PE ground terminals Drive size Screw size Torque SIZE A M4 2.5 N.m SIZE B M4 2.5 N.m SIZE C M4 2.5 N.m SIZE D M4 2.5 N.m Drive size Main circuit terminals SIZE A Screw size N/A Torque - SIZE B SIZE C N/A M4 - 2.5 N.m PE ground terminals Drive size Screw size Torque SIZE A M4 2.5 N.m SIZE B M4 2.5 N.m SIZE C M4 2.5 N.m rminal mark Terminal name Terminal function L1C, L2C Control power inpu terminal t Input single-phase voltage consistent with that of the main circuit power supply L1, L2, L3 Main circuit AC power input termin EA180□-0R9-1□ EA180□-1R6-1□ EA180□-2R5-1□ EA180□-4R8-2□ EA180□-6R2-2□ EA180□-010-2□ al EA180□-5R6-3□ EA180□-8R5-3□EA 180□-013-3□ EA180□-017-3□ EA180□-022-3□ EA180□-028-3□ L1, L2 single-phase 220V input L1, L2 single-phase 220V input or L1, L2, L3 3-phase 220V input L1, L2, L3 3-phase 220V input Three-phase 380V Supply Input