Technical Manual for EA350 Analog Pulse Type Servo Driver V101 Parameter functions: Activate a VDI terminal *: The letter B at the end of the number means the parameter value is expressed in binary, and shall be noted upon communication. When bitX=1, it means the VDI terminal corresponding to this bit is valid, and the function corresponding to this VDI terminal is activated. Caution ☞ 1. When the servo is restarted after power off, this parameter will be automatically set to zero. Parameter functions: Check the VDI terminal status *: The letter B at the end of the number means the parameter value is expressed in binary, and shall be noted upon communication.
When bitX=1, it means the VDI terminal corresponding to this bit is valid.
186 P6-55 VDI input control Initial value 00000000B Communication address 0637H Unit - Time of taking effect With immediate effect Setting range 00000000B~11111111B Data size 16bit Control mode P S T P6-56 VDI input status Initial value 00000000B Communication address 0638H Unit - Time of taking effect Read-only parameter Setting range 00000000B~11111111B Data size 16bit Control mode P S T P6-57 VDO1 function selection Initial value 0 Communication address 0639H Unit - Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P6-58 VDO2 function selection Initial value 0 Communication address 063AH Unit - Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P6-59 VDO3 function selection Initial value 0 Communication address 063BH Unit - Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P6-60 VDO4 function selection Initial value 0 Communication address 063CH Unit - Time of taking effect Cannot be modified Setting range 0~99 Data size 16bit Control mode P S T P6-61 VDO5 function selection Initial value 1 Communication address 063DH Unit - Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P6-62 VDO6 function selection Initial value 0 Communication address 063EH Unit - Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T P6-63 VDO7 function selection Initial value 8 Communication address 063FH Unit - Time of taking effect Taking effect upon power-on again Setting range 0~99 Data size 16bit Control mode P S T