Technical Manual for EA350 Analog Pulse Type Servo Driver V101 combination of the thousands and hundreds places. See section 6.6 for details. Parameter functions: Set the upper limit for revolutions of the absolute type encoder If the number of revolutions of the absolute type encoder is a positive number exceeding the set value, and the current command is in the forward direction, it shall be processed as a forward overrun. If the LED shows , WARN terminal output is valid; if the number of revolutions is a negative value exceeding the setting, and the current command is in the reverse direction, it shall be processed as a reverse overrun.

If the LED shows , the WARN terminal output is valid. Parameter functions: Select the usage of the absolute type encoder P8-06=0 : Used as an incremental encoder P8-06=1 : Used as an absolute type encoder 197 P8-05 Upper limit for revolutions of absolute type encoder Initial value 32767 Communication address 0805H Unit rev Time of taking effect With immediate effect Setting range 1~32767 Data size 16bit Control mode P S T P8-06 Selection of the usage for absolute type encoder Initial value 0 Communication address 0806H Unit - Time of taking effect Taking effect upon power-on again Setting range 0~1 Data size 16bit Control mode P S T