8.13.1.2 Seal The seal between the tub and the heating element is provided by a seal which expands against the nut. 1. Fixed flange 2. Washer 3. Moving flange 4. Nut 5. Heating element terminals 8.13.2 Electrical symbol 8.13.3 Checking for efficiency DOES NOT HEAT: - check that the heating element is not broken: measure the resistance across the two terminals. INTERVENTION OF ELECTRICAL SAFETY CUT-OUTS: - use an ohmmeter to check that the heating element is not connected to mass and check for current leakage (40 M Ω ) WATER LEAKS: - check that the seal is correctly positioned and fitted. VIBRATION OR METALLIC NOISE WHEN THE DRUM ROTATES:
- check that the heating element is correctly positioned inside the tub. If worn, replace the heating element. SOI/DT 2002-05 eb 84 599 35 23-17