sinee — 4.2 LED Keypad Operation Mode

EM500 Open-Loop Vector Control Inverter User Manual 4.2 LED Keypad Operation Mode 4 menu levels of LED keypad: Monitoring (level 0), menu mode selection (level 1), function code selection (level 2) and parameter value (level 3). In the following parts, menu levels are represented by figures. user-defined mode (--U--), only displays function parameters selected by user through 3 parameter display modes: All menu mode (--A--) displays all function codes; F11 group; non-factory defaults (--C--), only displays those function codes that are different from factory setting.

When keypad is powered, default display is the first monitoring parameter of level 0; 61 Frequency Indicator On when present parameter is frequency. Current Indicator On when present parameter is current. Voltage Indicator On when present parameter is voltage. Percentage Indicator On when present parameter is percentage. Forward/Reverse Indicator On at frequency is negative. On at running is reversed Communication Control Indicator On when F00.02 is set to keypad control, Off when F00.02 is set to terminal control Flickers when F00.02 is set to communication control Status Indicator On when inverter is running Flickers when stopping, off after stop.

Fault Indicator On when inverter is in fault state.