EM500 Open-Loop Vector Control Inverter User Manual 77 10: Process PID 11: Simple PLC F00.06 Frequency Source Options 0: Main Frequency Source A 1: Auxiliary Frequency Source B 2: Main and Auxiliary Arithmetic Results 3: Switching between Main Frequency Source A and Auxiliary Frequency Source B 4: Switching between Main Frequency Source A and Main & Auxiliary Arithmetic Results 5: Switching between Auxiliary Frequency Source B and Main & Auxiliary Arithmetic Results 6:Auxiliary Frequency Source B+ Feedforward arithmetic(Winding application) 0 〇 F00.07 Numeric Frequency Setting 0.00 Hz - Maximum Frequency F00.16 Hz 50.00 ● F00.08 Main and Auxiliary Arithmetic 0:
Main Frequency Source A + Auxiliary Frequency Source B 1: Main Frequency Source A - Auxiliary Frequency Source B 2: The Bigger of Main A and Auxiliary B 3: The Smaller of Main A and Auxiliary B 0 〇 F00.09 Reference Option for Auxiliary Frequency Source B at Main and Auxiliary Arithmetic 0: Relative to Maximum Frequency 1: Relative to Main Frequency Source A 0 〇 F00.10 Main Frequency Source Gain 0.0 - 300.0 % 100.0 ● F00.11 Auxiliary Frequency Source Gain 0.0 - 300.0 % 100.0 ● F00.12 Synthetic Gain of Main and Auxiliary Frequency 0.0 - 300.0 % 100.0 ● F00.13 Analog Adjustment 0: Synthetic Frequency of Main and 0 〇