EM500 Open-Loop Vector Control Inverter User Manual 84 90-103: Not Used 104: Inlet Pool Upper Limit Water Level Signal 105: Inlet Pool Lower Limit Water Level Signal 106: Inlet Pool Lack Of Water Level Signal 107: Sewage Pool Upper Limit Water Level Signal 108: Sewage Pool Lower Limit Water Level Signal 109: Not Used 110: External Overpressure Signal 111: Not Used 112: Switch The Pump 113~120: Not Used 121: External Signals Of Material supply disruptions 122: Winding traverse Detection Signal 123: Braking Reset Terminals F02.15 Positive/Negative Logic 1 of Numeric Input Terminal D7 D6 D5 D4 D3 D2 D1 D0 *00 00000 〇 * X7 X6 X5 X4 X3 X2 X1 0: Positive Logic, Enabled at On/Disabled at Off 1:
Negative Logic, Disabled at On/Enabled at Off F02.16 Positive/Negative Logic 2 of Numeric Input Terminal D7 D6 D5 D4 D3 D2 D1 D0 000 00000 〇 X11 X10 X9 X8 AI4 AI3 AI2 AI1 0: Positive Logic, Enabled at On/Disabled at Off 1: Negative Logic, Disabled at On/Enabled at Off F02.17 Filter Times of Numeric Input Terminal 0-100, 0 for No Filter, n for sampling once every n ms 2 〇 F02.18 X1 Effective Delay Time 0.000 - 30.000 s 0.000 ● F02.19 X1 Ineffective Delay Time 0.000 - 30.000 s 0.000 ● F02.20 X2 Effective Delay 0.000 - 30.000 s 0.000 ●