sinee — 6.2 Function Parameter Table

EM500 Open-Loop Vector Control Inverter User Manual 88 F02.53 Input of Inflexion 2 of Curve 4 F02.51 - F02.55 V 5.00 ● F02.54 Setting Corresponding to Input of Inflexion 2 of Curve 4 –100.0 - +100.0 % 50.0 ● F02.55 Maximum Input of Curve 4 F02.53 - 10.00 V 9.90 ● F02.56 Setting Corresponding to Maximum Input of Curve 4 –100.0 - +100.0 % 100.0 ● F02.57 AI1 Filter Time 0.00 - 10.00 s 0.10 ● F02.58 AI2 Filter Time 0.00 - 10.00 s 0.10 ● F02.59 AI3 Filter Time 0.00 - 10.00 s 0.10 ● F02.60 AI4 Filter Time (Expansion Card) 0.00 - 10.00 s 0.10 ● F02.61 AD Sampling Hysteresis 2 - 50 2 〇 F03 Output Terminal Function Group F03.00 Y1 Output Function 0: No Output 1: Inverter Running (RUN) 2:

Frequency Reach Range (FAR) 3: Output Frequency Detection Range FDT1 4: Output Frequency Detection Range FDT2 5: Reverse running (REV) 6: Jogging 7: Inverter Fault 8: Inverter Ready 9: Upper Limit Frequency Reach 10: Lower Limit Frequency Reach 11: Current Limit Enabled 12: Overvoltage Stall Enabled 13: Simple PLC Cycle Finished 14: Set Count Value Reach 15: Designated Count Value Reach 16: Length Reach 17: Motor Overload Pre-alarming 1 ○ F03.01 Y2 Output Function 3 ○ F03.02 R1 Output Function (EA-EB-EC) 7 ○ F03.03 R2 Output Function (RA-RB-RC) 8 ○ F03.04 Y3 Output Function (expansion card) 0 ○