EM500 Open-Loop Vector Control Inverter User Manual 95 F05.15 Sagging Control Frequency 0.00 - 10.00 Hz 0.00 ● F05.16 Energy Saving Rate 0.00 - 50.00 % 0.00 ● F05.17 Energy Saving Actuation Time 1.00 - 60.00 s 5.00 ● F05.18 Compensation Gain of Magnetic Flux of Synchronous Motor 0.00 - 500.00 % 100.00 ● F05.19 Filter Time Constant of Magnetic Flux Compensation of Synchronous Motor 0.00 - 10.00 s 0.50 ● F06 Vector Control Parameter Group F06.00 Speed Proportional Gain ASR P1 _ 0.00 - 100.00 12.00 ● F06.01 Speed Integral Time Constant ASR T1 _ 0.000 - 30.000 0.000:
No Integral s 0.200 ● F06.02 Speed Proportional Gain ASR P2 _ 0.00 - 100.00 8.00 ● F06.03 Speed Integral Time Constant ASR T2 _ 0.000 - 30.000 0.000: No Integral s 0.300 ● F06.04 Switching Frequency 1 0.00 - Switching Frequency 2 Hz 5.00 ● F06.05 Switching Frequency 2 Switching Frequency 1 - Maximum Frequency F00.16 Hz 10.00 ● F06.06 Speed Loop Anti-Saturation Factor 0.000 - 1.000 0.500 ● F06.07 Time Constant of Output Filter of Speed Loop 0.000 - 0.100 s 0.001 ● F06.08 Vector Control Slip Gain 50.00 - 200.00 % 100.00 ● F06.09 Speed control torque limit source selection 0: F06.10 and F06.11 1: AI1 2: AI2 3: AI3 4: AI4 (Expansion Card) 5: communication 6: maximum of AI2 and AI3 0 〇