sinee — 6.2 Function Parameter Table

EM500 Open-Loop Vector Control Inverter User Manual 97 F06.24 Proportional Gain of Field Weakening Regulator of Synchronous Motor 0.00 - 10.00 0.50 ● F06.25 Integral Time of Field Weakening Regulator of Synchronous Motor 0.00 - 6000.00 ms 100.00 ● F06.26 MTPA Control Options of Synchronous Motor 0: Disabled 1:

Enabled 0 〇 F06.27 Gain of Autotuning at Initial Position 0 - 600 % 80 ● F06.28 Frequency of Injection Current at Low Frequency Range 0.00 - 100.00 (100.00= Motor Rated Frequency) % 10.00 ● F06.29 Injection Current at Low Frequency Range 0.0 - 60.0 (100.0= Motor Rated Current) % 20.0 ● F06.30 Low Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F06.31 Integral Time of Low Frequency Range Regulator of Injection Current 0.00 - 300.00 ms 10.00 ● F06.32 Frequency of Injection Current at High Frequency Range 0.00 - 100.00 (100.00= Motor Rated Frequency) % 20.00 ● F06.33 Injection Current at High Frequency Range 0.0 - 30.0 (100.0= Motor Rated Current) % 8.0 ● F06.34 High Frequency Range Regulator Gain of Injection Current 0.00 - 10.00 0.50 ● F06.35 Integral Time of 0.00 - 300.00 ms 10.00 ●