sinee — 1.2.3 Setting Modes of inverter

EM600 High-Performance Vector Control Inverter User Manual Preset speed n F08.00 – F08.14 0: Numeric frequency setting F00.07 UP/DOWN setting n=1,2,…,15 0 1 2 3 4 5 1: AI1 * F00.16 2: AI2 * F00.16 + Preset speed terminal DI: 14 - 11 0 Main frequency switching DI: 51 – 56 Disabled Main frequency source A F00.04 3: AI3 * F00.16 + + Main frequency source gain F00.10 Enabled AI1 AI2 AI3 HDI(脉冲) F00.07 6 5: HDI * F00.16 4: AI4 * F00.16 + 6: SCI * F00.16 Communication HDI (pulse) 通讯 Figure 1-2 Main Frequency Source A Setting As indicated in Figure 1-2, when setting main frequency source A, user needs to consider settings and status of numeric terminals comprehensively.

According to terminal settings, inverter runs at a preset speed or at a speed determined through numeric setting, analog quantity, pulse or communication. If all the terminals are disabled, F00.04 is used to set present setting channel, which then will be in arithmetic together with UP/DOWN to get final setting. Figure 1-3 Auxiliary Frequency Source B Setting As indicated in Figure 1-3, when auxiliary frequency source B is being set, setting of F00.05 will be based upon to determine present setting channel. Process PID and Simple PLC can be involved in setting. 13