EM630/TC6A Closed-Loop Vector Hoist Inverter User Manual 41 Terminal Mode Terminal Terminal Function No. Terminal 2 select the voltage/current mode by the switch S4 on the terminal block Input impedance: voltage mode 1MΩ, current mode 250Ω Input range: DC 0 - 10V/0 - 20mA; select the voltage/current mode by the Analog Input AI3-GND switch S5 on the terminal block. Terminal 3 Input impedance: voltage mode 1MΩ, current mode 250Ω Multi-function X1-COM Input Terminal 1 Multi-function X2-COM Input Terminal 2 Multi-function Optocoupler isolation, compatible with X3-COM Input Terminal 3 bipolar input of NPN and PNP. Multi-function Input impedance: 4.5 kΩ X4-COM Input Terminal 4 Input voltage range:
9 - 30V Multi-function X5-COM Numeric Input Input Terminal 5 Multi-function X6-COM Input Terminal 6 In addition to being used as multi-function input terminal, it can be used as high speed pulse input terminal High Speed Pulse X7-COM as well with the maximum response Input Terminal frequency of 100 kHz. Input voltage: 12 - 48V Input impedance: 1 kΩ Output range: DC 0 - 10V/0 - 20mA; Analog Output M1-GND selected by the switch S2 on the terminal Terminal 1 block. Analog Output Output range: DC 0 - 10V/0 - 20mA; Analog Output M2-GND selected by the switch S3 on the terminal Terminal 2 block. Optocoupler isolation, OC output Multi-Function OC Output Y1-COM Maximum output voltage:
DC48V Output Terminal Output current: 50mA