User Guide of EM730 Series Inverter 106 F27.16 Feedforward increment 3 0.00 - 50.00 %/S 0.75 ● F27.17 Feedforward increment 4 0.00 - 50.00 %/S 1.55 ● F27.18 Feedforward increment 5 0.00 - 50.00 %/S 4.00 ● F27.19 Feedforward increment 6 0.00 - 50.00 %/S 11.00 ● F27.20 Material cutoff control mode Ones place: Disconnection detection mode 0: Automatic detection 1: External signal Tens place: Material cutoff detection control 0: Detect when the output is greater than the lower limit of material cutoff detection 1: no detection Hundreds place: Material cutoff handling mode 0: Protection of terminal action only 1: Delayed stop and trip protection 2: Material cutoff protection 3:
Automatic reset after protection shutdown 4: Material cutoff detection terminal output only (straight wire drawing machine) 5: Automatic reset of cutoff detection terminal (straight wire drawing machine) Thousands place: Brake mode 0: mode 0 1: mode 1 Myriabit: Reverse unwinding mode 0: No speed limit 1: Reverse speed limit by F27.24 01201 〇 F27.21 Material cutoff detection delay 0.0~10.0 S 6.0 ● F27.22 Lower limit of material cutoff detection after parking 0.00 - 60.00 Hz 5.00 ● F27.23 Time of continuous running after material cutoff 0.0 - 60.0 S 10.0 ● F27.24 Frequency of continuous 0.00~Fmax Hz 5.00 ●