User Guide of EM730 Series Inverter 63 control 1:AI1 2:AI2 3: retention 4: retention 5: high frequency pulse input (X5) 6: Communication setting (percentage) 7: Communication setting (direct frequency) F00.18 Upper frequency limit Lower frequency limit F00.19 to maximum frequency F00.16 Hz 50.00 ● F00.19 Lower frequency limit 0.00 to upper frequency limit F00.18 Hz 0.00 ● F00.20 Running direction 0: consistent direction 1: opposite direction 0 ● F00.21 Reverse control 0: Allow forward/reverse running 1: Prohibit reversing 0 〇 F00.22 Duration of forward and reverse dead zone 0.00~650.00 s 0.00 ● F00.23 Carrier frequency 1.0-16.0 (rated power of the inverter:
0.75-4.00kW) 1.0-10.0 (rated power of the inverter: 5.50-7.50kW) 1.0 - 8.0 (rated power of inverter 11.00 - 45.00kW) 1.0 - 4.0 (rated power of inverter 55.00 - 90.00kW) 1.0-3.0 (rated power of inverter: 110.00 and above) kHz 4.0 (0.75 and below) /2.0 ● F00.24 Automatic adjustment of carrier frequency 0: Invalid 1: valid 1 2: Valid 2 1 〇 F00.25 Noise suppression of carrier frequency 0: Invalid 1: valid 0 〇 F00.26 Noise suppression tone 20~200 Hz 40 ● F00.27 Noise suppression intensity 10~150 Hz 100 ● F00.28 Options of motor parameter group 0: parameter group of motor 1 1: parameter group of motor 2 0 〇 F00.29 User password 0 - 65535 0 〇 F00.31 Frequency resolution 0:0.01Hz 1:
0.1Hz (speed unit: 10rpm) 0 〇 F00.35 Power supply voltage selection 0: 380V 1: 440V 0 〇 F01 Parameter group of motor 1 F01.00 Motor type 0: ordinary asynchronous motor 1: variable-frequency asynchronous motor 2: permanent magnet synchronous motor 0 〇 F01.01 Rated power of electric motor 0.10~650.00 kW Depending on the motor type 〇 F01.02 Rated voltage of motor 50~2000 V Depending 〇