sinee — 9.2 Table of functional parameters

User Guide of EM730 Series Inverter 79 processing of synchronous motor 2:

IF in start and VF in stop F06.42 Open-loop low-frequency processing range of synchronous motor 0.0 - 50.0 % 8.0 〇 F06.43 IF injection current 0.0 - 600.0 % 50.0 〇 F06.44 Time constant of pull-in current of magnetic pole 0.0 - 6000.0 ms 1.0 〇 F06.45 Initial lead angle of magnetic pole 0.0~359.9 ° 30.0 〇 F06.46 Speed tracking proportional gain of synchronous motor 0.00 - 10.00 1.00 〇 F06.47 Speed tracking integral gain of synchronous motor 0.00 - 10.00 1.00 〇 F06.48 Filtering time constant of speed tracking of synchronous motor 0.00 - 10.00 ms 0.40 〇 F06.49 Speed tracking control intensity of synchronous motor 1.0 - 100.0 5.0 〇 F06.50 Speed tracking control threshold of synchronous motor 0.00 - 10.00 0.20 〇 F06.51 Rise time of 0.010 - 1.000 s 0.020 〇