User Guide of EM730 Series Inverter 92 SCI sending timeout resetting F10.59 SCI response option 0: Reply to both read and write commands 1: Reply to write commands only 2: No reply to both read and write commands 0 〇 F11 User-selected parameter group (Detail in EM730 User Manual) F12 Keyboard and display function group F12.00 M.K multi-function key options 0: no function 1: forward jog 2: reverse jog 3: forward/reverse switching 4: quick stop 5: free stop 6. Cursor left 1 〇 F12.01 Options of stop function of STOP key 0: valid only in keyboard control 1: with all command channels valid 1 〇 F12.02 Parameter locking 0: do not lock 1: reference input not locked 2:
all locked, except for this function code 0 ● F12.03 Parameter copying 0: No operation 1: parameter upload to keyboard 2: Download parameters to inverter 0 〇 F12.09 Load speed display coefficient 0.01~600.00 30.00 ● F12.10 UP/DOWN acceleration and deceleration rate 0.00: automatic rate 0.05~500.00Hz/s 5.00Hz/s 〇 F12.11 Options of UP/DOWN offset clearing 0: Not clear (clear changes in main frequency setting) 1: clear in non-running state 2: Clear by releasing the UP/DOWN button 0 〇 F12.12 Options of UP/DOWN power-down saving of offset 0: do not save 1: save (valid after the offset is modified) 1 〇 F12.13 Power meter resetting 0: do not clear 1:
clear 0 ● F12.14 Restoration of factory defaults 0: No operation 1: restoration of factory defaults (excluding the motor parameters, inverter parameters, manufacturer parameters, running and power-on time record) 0 〇 F12.15 Cumulative 0~65535 h XXX ×