User Manual of EM730/EM730E Series Inverter 112 F14.78 Maximum frequency of motor 2 20.00~600.00 Hz 50 〇 F14.79 Upper frequency limit of motor 2 Lower limit frequency F00.19 to maximum frequency F14.78 Hz 50 ● F14.80 V/F curve setting of motor 2 0: straight line V/F 1: multi-point broken line V/F 2: 1.3-power V/F 3: 1.7-power V/F 4: square V/F 5: VF complete separation mode (Ud = 0, Uq = K * t = voltage of separation voltage source) 6:
VF semi-separation mode (Ud = 0, Uq = K * t = F/Fe * 2 * voltage of separation voltage source) 0 〇 F14.81 Multi-point VF frequency F1 of motor 2 0.00 - F14.83 Hz 0.50 ● F14.82 Multi-point VF voltage V1 of motor 2 0.0~100.0 (100.0 = Rated voltage) % 1.0 ● F14.83 Multi-point VF frequency F2 of motor 2 F14.81 - F14.85 Hz 2.00 ● F14.84 Multi-point VF voltage V2 of motor 2 0.0-100.0 % 4.0 ● F14.85 Multi-point VF frequency F3 of motor 2 F14.83 to rated frequency of motor (reference frequency) Hz 5.00 ● F14.86 Multi-point VF voltage V3 of motor 2 0.0-100.0 % 10.0 ● F14.87 Stop mode of motor 2 0: Slow down to stop 1:
free stop 0 〇 F14.96 Low speed correction factor of stator resistor of asynchronous motor 2 10.0~500.0 % 100.0 ● F14.97 Low speed 10.0~500.0 % 100.0 ●