User Manual of EM730/EM730E Series Inverter 120 positive/nega tive logic 0: positive logic, valid in the closed state/invalid in the open state 1: Negative logic, invalid in the closed state/valid in the open state F17.28 Control options of virtual output terminal D7 D6 D5 D4 D3 D2 D1 D0 11111 〇 VY8 VY7 VY6 VY5 VY4 VY3 VY2 VY1 0: Depending on the status of terminal X1-X5 (without VY6-8) 1:
depending on the output function status F17.29 VY1 valid delay time 0.000-30.000 s 0.000 ● F17.30 VY1 invalid delay time 0.000-30.000 s 0.000 ● F17.31 VY2 valid delay time 0.000-30.000 s 0.000 ● F17.32 VY2 invalid delay time 0.000-30.000 s 0.000 ● F17.33 VY3 valid delay time 0.000-30.000 s 0.000 ● F17.34 VY3 invalid delay time 0.000-30.000 s 0.000 ● F17.35 VY4 valid delay time 0.000-30.000 s 0.000 ● F17.36 VY4 invalid delay time 0.000-30.000 s 0.000 ● F17.37 Virtual input terminal status VX8 VX7 VX6 VX5 VX4 VX3 VX2 VX1 000 00000 × 0: Invalid 1: valid F17.38 Virtual output terminal status VY8 VY7 VY6 VY5 VY4 VY3 VY2 VY1 00000 × 0: Invalid 1:
valid F18 Monitoring parameter group F18.00 Output frequency 0.00 to upper frequency limit Hz XXX × F18.01 Set frequency 0.00 to maximum frequency F00.16 Hz XXX × F18.03 Estimate feedback frequency 0.00 to upper frequency limit Hz XXX × F18.04 Output torque -200.0 - 200.0 % XXX ×