User Manual of EM730/EM730E Series Inverter 126 F27.06 Feedforward gain filter time 0~1000 ms 0 ● F27.07 Feedforward range 0 0.00 to feedforward range 1 % 4.00 ● F27.08 Feedforward range 1 Feedforward range 0 to feedforward range 2 % 12.00 ● F27.09 Feedforward range 2 Feedforward range 1 to feedforward range 3 % 23.00 ● F27.10 Feedforward range 3 Feedforward range 2 to feedforward range 4 % 37.00 ● F27.11 Feedforward range 4 Feedforward range 3 to feedforward range 5 % 52.00 ● F27.12 Feedforward range 5 Feedforward range 4 to 100.00 % 72.00 ● F27.13 Soft start increment 0.00 - 50.00 %/S 0.60 ● F27.14 Feedforward increment 1 0.00 - 50.00 %/S 0.11 ● F27.15 Feedforward increment 2 0.00 - 50.00 %/S 0.30 ● F27.16 Feedforward increment 3 0.00 - 50.00 %/S 0.75 ● F27.17 Feedforward increment 4 0.00 - 50.00 %/S 1.55 ● F27.18 Feedforward increment 5 0.00 - 50.00 %/S 4.00 ● F27.19 Feedforward increment 6 0.00 - 50.00 %/S 11.00 ● F27.20 Material cutoff control mode Ones place:

Disconnection detection mode 0: Automatic detection 1: External signal Tens place: Material cutoff detection control 0: Detect when the output is greater than the lower limit of material cutoff detection 1: no detection Hundreds place: Material cutoff handling mode 0: Protection of terminal action only 1: Delayed stop and trip protection 2: Material cutoff protection 3: Automatic reset after protection shutdown 4: Material cutoff detection terminal output only (straight wire drawing machine) 5: Automatic reset of cutoff 01201 〇