sinee — EM730 User Manual (EN)

User Manual of EM730/EM730E Series Inverter Table 7-3 Detailed Setting of Main Frequency Source A F00.05=0: digital frequency setting F00.07 The auxiliary frequency B depends on the digital frequency setting F00.07. F00.05=1:AI1 F00.05=2:AI2 The auxiliary frequency B is determined by AI (percentage) * F00.16. For the details of AI1 and AI2, refer to the F00.04 description. They have the same 135 Terminal Function Status Description Priority 11-14: multi-segment speed terminals 1-4 If one is valid, the multi-segment speed mode will be enabled (F08.00-F08.14). 1 51:

switching of main frequency source to digital frequency setting Valid, depending on the digital frequency setting F00.07, the same as the function code F00.04=0 2 52: switching of main frequency source to AI1 Valid, depending on the AI1 input percentage setting, the same as the function code F00.04=1 3 53: Switching of main frequency source to AI2 Valid, depending on the AI2 input percentage setting, the same as the function code F00.04=2 4 56:

switching of main frequency source to communication setting Valid, depending on the communication input, the same as the function code F00.04=6 7 -- All invalid, depending on the setting of function code F00.04 8 Function Default Function code name Parameter description Unit Attribute code setting F00.05 Options of auxiliary frequency source B 0: digital frequency setting F00.07 1: AI1 2: AI2 3: retention 4: retention 5: high frequency pulse input (X5) 6: percent setting of auxiliary frequency communication 7: direct setting of auxiliary frequency communication 8: digital potentiometer setting 9: retention 10: process PID 11: simple PLC 0 〇